The Best LTE filters for TV antennas: What they are and do you need one?

LTE filters for TV antennas: What they are and do you need one? - LTE broadbans signals interfere TV reception , mostly for Digital TV reception, By using this filter, the TV signal will be clean from interference from the influence of the LTE signal. 

LTE Filters

Amplifiers, LTE Filter

New passive filters have been designed for the attenuation of signals that will be transmitted over the telephone band called 4G (ex Television UHF channels E61 .. E69). These filters differ in selectivity and kind of use. They are all made with die casting or IEC connectors, in order to make them suitable to be inserted at any point in the distribution system. The two best performing models, as regards the steepness of the cut between TV band and 4G band (LTE), are made according to up-to-date technology and respond to the specifications included in the CEI guide 100-7 (typical case). The A+ Class filters are realized by variable capacitors technology. This product is used to solve pronounced LTE interference problems. All the other models have a less pronounced transition, are made with LC-type cells, and can be used to integrate the above described models, or where the risk of interference is not low. 







LC cell standard filters

  • Filter for mast 83124L59, calibrated on ch.59
  • Filter for mast 83124L
  • In-line filter for outdoor 81949L
  • Filter for insertion into the antenna 81942FL
  • Filter for insertion into the amplifier 81947L
  • Rear-TV filter or plug 81948L
A+ Class filters
  • Filter for mast 83125L
High performance filters in accordance with CEI norms
  • Filter LTE TELCO high performance for mast 83124LH
  • Filter LTE TELCO high performance for indoor 81949LH

  • Ref.ArticleConnecteursPass BandOutdoor useReturn Loss [dB]Through Loss [ dB ]







    Size [mm]






    40- 778 778 - 786 790791793794-810810-820820- 870 (MHz)

    Standard Filters














    81947LFLFF/f F/mDC - 790 MHzyes100,4 ..2,5 2,5..4,5 77.511.512 .. 55 > 55 > 55
    82x26x17
    81948LFLTVIEC/m IEC/fDC - 790 MHzno100,4 ..2,5 2,5..4,5 77.511.512 .. 55 > 55 > 55
    82x26x18
    81949LFLEF/f F/fDC - 790 MHzno100,4 ..2,5 2,5..4,5 77.511.512 .. 55 > 55 > 55
    82x26x19
    83124LFLPF/f F/fDC - 790 MHzyes100,4 ..2,5 2,5..4,5 77.511.512 ..55 > 55 > 55
    92x56x32
    83124L59FLPF/f F/fDC - 790 MHzsi100,4 ..3,53,5..1119.42227> 45> 45> 45
    92x56x33
    81942FLFLDF/m F/fDC - 790 MHzyes100,5 ..3,0 3,0..4,5 55.588 .. 45 > 45 > 55
    63x17x17
    Filtri Classe A+














    83125LFLCVF/f F/fDC - 790 MHzyes100,5 ..3,0 3,0..5,57.5

    >30> 45 > 55
    130x110x65
    TELCO Filters CEI 100-7 guide














    81949LHFLTEF/f F/fDC - 790 MHzno10< 1,5< 26

    >30>30>20
    117x33x17
    83124LHFLTE1F/f F/fDC - 790 MHzyes10< 1,5< 26

    >30>30>20
    121x41x27

No comments: